Single toilet restrooms should have a door that can be locked from the inside.
Commercial bathroom stall size.
Small public restrooms figs.
Sight line fillers are available.
Other than code minimums good practice and todays growing expanding bodies imply a minimum clear stall width of 36 with no less than 30 from the inside face of the stall door to the front lip of the stool.
Generally stall doors open inward but for ada accessible stalls the doors should open outward to make it easier for those with accessibility devices to enter and exit.
Multiple toilet restrooms should feature stalls and partitions that provide the necessary privacy.
Minimum 60 inch 1525mm diameter or t shaped turning spaces are also required as well as an accessible lavatory restroom accessories and access aisles that meet 2010 ada and 2009 icc ansi standards.
While the numbers may vary in accordance with the unique characteristics of your bathroom space a standard toilet stall is 36 inches wide and 60 inches deep.
You want to make sure you are measuring exactly where the partitions will be placed because bathrooms are not always exactly square.
We carry standard 58 sized bathroom partitions and more customized 64 and 72 high doors and panels.
Quotes returned within hours.
The minimum depth for a partition stall is 48 inches but the depth can be as much as 78 inches if necessary.
In a corner handicap stalls require a minimum of 60 x 60 compartment and is required with a minimum door size of 32 and the maximum size and more common is the 36 door.
One alternate stall is required to be 36 inches 915 mm wide.
However stall depth can be anywhere between 48 inches to 78 inches as needed.
Restroom partitions are inventoried to ship.
Typically bathroom stalls are floor mounted with an overhead bracing.
Standard toilet stalls are 36 wide by 60 depth.
For commercial bathrooms with multiple toilet stalls and handicap the rules change a little.
In either alternate stall if a wall mounted water closet is used the depth of the stall is required to be a minimum of 66 inches 1675 mm.
17 19 require one standard 60 inch 1525mm wide toilet compartment.
Ask about increased privacy partitions.
Partition stalls can have a minimum depth of 48 in most cases or up to 78 depth if needed.
Bathroom stalls that accommodate ada requirements should be at least 60 inches wide 152 cm and 59 inches 150 cm deep on the inside.
Standard bathroom stall sizes rarely vary and tend to be 36 inches wide and 60 inches deep.
Call 1 866 255 8645 get an accurate quote by sending us a sketch of your restroom stall plans.
The other alternate stall is required to be a minimum of 48 inches 1220 mm wide.
Two alternate stalls are permitted for alterations only.
Preferable for door to swing out obesity is an epidemic and is not going away soon.